VM ZINC homepage









Standing seam systems:
Warm (cellular glass)
Warm (mineral wool/PIR)
Warm (composite panels)

Ventilated (roof boarding)
Ventilated roof (incompatible support)




Website Umicore
 
Roofing systems
Facade systems
Pluline gutters
Ornaments

















This website technical and commercial contents applies exclusively to the specification and installation of the designated products or systems on building sites in United Kingdom and the Republic of Ireland. For all other countries please consult vmzinc.com.

Feel free to choose any form our aspect
 
 
Standing seam Print E-mail

Warm roof on mineral wool or PIR


  • Roofs with a pitch from 3° to 45°
  • On all structures compa-tible with the installation of cellular glass
  • Non-penetrating fastening
  • Transformation, installation in sheets up to 13 m long, mechanical crimping
 
AREA OF APPLICATION

  • Roofs with a pitch from 3° to 60°.
  • Classes of internal humidity load: 1 to 4.
 


VM ZINC®, the choices
Only "PLUS" type VM ZINC®
with a specially protected underside: Natural VM ZINC® PLUS,  QUARTZ-ZINC® PLUS, ANTHRA-ZINC® PLUS, PIGMENTO® VM ZINC® PLUS: 0.7 mm thick.

VM ZINC PLUS

Characteristics of this technique
With this warm roof system VM ZINC® PLUS standing seam can be installed on mineral wool or PIR insulation without ventilating the underside of the VM ZINC® PLUS.
Penetrating fixing elements can be used with the help of plates, joists or special fixing clips supplied by Umicore.

 

Structure

A choice of:
  • Steel deck.
  • Timber deck.

This structure is successively covered by:
  • A vapour control layer with a high water vapour resistance installed with cold or hot glued joints.
  • Insulation: either mineral wool or some types of PIR. all insulation materials have to resist a compression strenght of minimum 50kPa (0.5kg/cm²), at a maximum 10% deformation.
    The insulation must have the necessary approvals for use in warm roof applications.
  • Between the VM ZINC® PLUS and the insulation, a breather membrane is fixed with an overlap of + 150 mm.

N.B.  The information relating to the installation of insulation and membranes is simply an indication.
The choice and installation of these products will be according to the recommendations of the insulation and membrane manufacturers.
 

 Composition of the roof
1. Interior finish
2. Bearing structure (e.g. steel deck)
3. Vapour control layer
4. Insulation
5. Breather membrane
6. VM ZINC® PLUS standing seam
Image
 

Image

Standing seam
Guidelines for specification and installation


Edition 06/2007 (83 pages)
Erratum 09/2007 (page n°19)
PDF File (6,4 Mo)

-- Download --


Click here to download freely technical drawings in DWG format (Autocad 2000 versions)
Click here to create the  technical specifications of your project.